RAID6-2018: Unterschied zwischen den Versionen

Aus OrgaMon Wiki
Zur Navigation springen Zur Suche springen
Zeile 44: Zeile 44:


  [A.1  |A.2  |A.3  |A.4  ] [B.1  |B.2  |B.3  |B.4  ]
  [A.1  |A.2  |A.3  |A.4  ] [B.1  |B.2  |B.3  |B.4  ]
[HF0CFD|XLHK2N|<s>F7EL9R</s>|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]
  [HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]
  [HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]



Version vom 30. November 2018, 19:59 Uhr

Info

/dev/md127:
       Version : 1.2
 Creation Time : Sun Nov  8 00:30:12 2015
    Raid Level : raid6
    Array Size : 23441313792 (22355.38 GiB 24003.91 GB)
 Used Dev Size : 3906885632 (3725.90 GiB 4000.65 GB)
  Raid Devices : 8
 Total Devices : 8
   Persistence : Superblock is persistent

 Intent Bitmap : Internal

   Update Time : Tue Oct 16 16:34:23 2018
         State : clean
Active Devices : 8
Wrking Devices : 8
Failed Devices : 0
 Spare Devices : 0

        Layout : left-symmetric
    Chunk Size : 512K

          Name : Tokio:0
          UUID : 39c0b55f:74c0ab19:5f939236:16921f79
        Events : 269988

Cage Number Major Minor RaidDevice State
A3   0      8     81    0      active sync   /dev/sdf1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WMC130F7EL9R
A4   1      8     65    1      active sync   /dev/sde1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC134LLA4YE
A1   2      8     49    2      active sync   /dev/sdd1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC134HF0CFD
A2   3      8     33    3      active sync   /dev/sdc1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC133XLHK2N
B1   6      8     113   4      active sync   /dev/sdh1 ata-HGST_HDN724040ALE640_PK2338P4HGJ6RC
B2   5      8     97    5      active sync   /dev/sdg1 ata-HGST_HDN724040ALE640_PK2338P4HGDRYC
B4   4      8     17    6      active sync   /dev/sdb1 ata-HGST_HDN724040ALE640_PK1334PCKNY90X
B3   7      8     1     7      active sync   /dev/sda1 ata-HGST_HDN724040ALE640_PK1334PEHYT9XS

Lage der Platten


[A.1   |A.2   |A.3   |A.4   ] [B.1   |B.2   |B.3   |B.4   ]
[HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]
[HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]

Beschaffung

Es sollen schrittweise alle Platten durch 8 TB Exemplare ersetzt werden.
https://www.alternate.de/html/listings/1458214498740?order=ASC&lk=8323&showFilter=false&hideFilter=false&disableFilter=false&filter_-1=3500&filter_-1=142900&filter_1021=8000.0&filter_2147482612=1037

Ereignisse

May 09 01:22:50 tokio kernel: blk_update_request: I/O error, dev sdf, sector 7010129740
May 09 01:22:53 tokio kernel: blk_update_request: I/O error, dev sdf, sector 7010129740
Jul 26 01:22:52 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521277045
Jul 26 01:22:54 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521277045
Jul 26 01:22:57 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521278897
Jul 26 01:22:59 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521278897
Oct 18 01:18:41 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6620009643
Oct 18 01:18:44 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6620009643
27.11.2018 9 Uhr Ausfall von 2 Platten, sieht aus wie ein kurzes "Power Fail" Event
           11 Uhr Anfrage wegen zu wenig Platz, Reduziere Sicherungen von 10 auf 7
           Lösche die Sicherungsverzeichnisse 7+8+9
           stelle den Ausfall von 2 Platten fest
           rebuild von Platte sdd
28.11.2018 rebuild von Platte sdg
           I/O Fehler bei Platte sdf aus der Vergangenheit entdeckt
           Beschaffung einer neuen 8TB Platte, soll "sdf" ersetzen
30.11.2018 neue Platte als 9. Platte hinzugehängt
           --add-spare & --replace angestossen
           + ata-ST8000VN0022-2EL112_ZA1CY63J (sdi)
           - ata-WDC_WD4000FYYZ-01UL1B2_WD-WMC130F7EL9R (sdf)