RAID6-2015

Aus OrgaMon Wiki
Zur Navigation springen Zur Suche springen
4 TB nutzbare Kapazität

6x 1 TB Platten
1x 1 TB Platte als Spare
1x Systemplatte 2,5" SSD

Layout

[Tue Dec 10 19:52:56 2019]  disk 0, o:1, dev:sdd1
[Tue Dec 10 19:52:56 2019]  disk 1, o:1, dev:sdh1
[Tue Dec 10 19:52:56 2019]  disk 2, o:1, dev:sdf1
[Tue Dec 10 19:52:56 2019]  disk 3, o:1, dev:sde1
[Tue Dec 10 19:52:56 2019]  disk 4, o:1, dev:sdc1
[Tue Dec 10 19:52:56 2019]  disk 5, o:1, dev:sda1


  • A1|A2|A3|A4|B1|B2|B3|B4 (Bay-Bezeichnungen von Links nach Rechts)
Eigenschaften/Bay A1 A2 A3 A4 B1 B2 B3 B4
laufende Nummer 1 2 3 4 5 6 7 8
SATA-Kabel rot rot rot rot
Markierung schwarz
rot rot rot rot
Serial 32647390 (55890888)
neu:Z1N3WJ16
Z1N07LHT * 36643628 32644607 (Z1N4BWDK)
neu:?
3NCSLRE
/dev/disk/by-id ata-WDC_WD1003FBYX-01Y7B0_WD-WCAW32647390 ata-WDC_WD10EADS-11M2B1_WD-WCAV55890888 ata-ST1000NM0011_Z1N07LHT ata-WD1003FBYX-23_00W1138_00W1442IBM_WD-WCAW36643628 ata-WDC_WD1003FBYX-01Y7B0_WD-WCAW32644607 ata-ST1000NM0011_Z1N4BWDK ata-WDC_WD10PURX-64E5EY0_WD-WCC4J3NCSLRE
Devicename /sdd/ /sdb/ /sdg/ (/sda/) /sdc/ /sde/ /sd?/ /sdh/
RAID-Device 5 2 0 NICHT TEIL DES ARRAY!
SYSTEM PLATTE!
4 3 SPARE 1
* hier ist die Systemplatte eingebaut

Devices

/dev/md127:
       Version : 1.2
 Creation Time : Fri Nov 13 23:29:12 2015
    Raid Level : raid6
    Array Size : 3906521088 (3725.55 GiB 4000.28 GB)
 Used Dev Size : 976630272 (931.39 GiB 1000.07 GB)
  Raid Devices : 6
 Total Devices : 7
   Persistence : Superblock is persistent

 Intent Bitmap : Internal

   Update Time : Thu Mar  1 08:01:37 2018
         State : clean
Active Devices : 6
Working Devices : 7
Failed Devices : 0
 Spare Devices : 1

        Layout : left-symmetric
    Chunk Size : 512K


          Name : linux-9st1:0
          UUID : 2ca7d214:9c6bfab4:b2ecf28b:72df44ca
        Events : 23311

   Number   Major   Minor   RaidDevice State
      0       8       97        0      active sync   /dev/sdg1
      1       8       17        1      active sync   /dev/sdb1
      8       8       81        2      active sync   /dev/sdf1
      7       8       33        3      active sync   /dev/sdc1
      6       8       65        4      active sync   /dev/sde1
      5       8       49        5      active sync   /dev/sdd1

      9       8      113        -      spare   /dev/sdh1
/dev/md127:
       Version : 1.2
 Creation Time : Fri Nov 13 23:29:12 2015
    Raid Level : raid6
    Array Size : 3906521088 (3725.55 GiB 4000.28 GB)
 Used Dev Size : 976630272 (931.39 GiB 1000.07 GB)
  Raid Devices : 6
 Total Devices : 7
   Persistence : Superblock is persistent

 Intent Bitmap : Internal

    Update Time : Tue Oct 16 15:32:30 2018
          State : clean
 Active Devices : 6
Working Devices : 7
 Failed Devices : 0
  Spare Devices : 1

        Layout : left-symmetric
    Chunk Size : 512K


          Name : linux-9st1:0
          UUID : 2ca7d214:9c6bfab4:b2ecf28b:72df44ca
        Events : 25715

   Number   Major   Minor   RaidDevice State
      0       8       97        0      active sync   /dev/sdg1
      1       8      113        1      active sync   /dev/sdh1
      9       8       17        2      active sync   /dev/sdb1
      7       8       65        3      active sync   /dev/sde1
      6       8       33        4      active sync   /dev/sdc1
      5       8       49        5      active sync   /dev/sdd1

      8       8       81        -      spare   /dev/sdf1

Log-Buch

14.02.2016 Produktiv
      2017 Ausfall einer Platte, Platte hinzugefügt
28.02.2018 defekte Platte ausgebaut, Spare Platte dazugemacht
01.03.2018 Vollständiger Lesecheck OK
05.09.2018 sdf fiel durch I/O Errors auf, durch das spare ersetzt
12.10.2018 sdf durch eine neue Platte ersetzt (nur Hardware)
16.10.2018 sdf ist nun spare
30.11.2019 Vollständiger Lesecheck, sdb fiel durch Lesefehler massiv auf, durch spare sdf ersetzt
           Betrieb ohne Spare, jedoch read-check 100% ok
03.12.2019 Besuch vor Ort, geklappere am Server, "sdf" wird vom raid6 rausgeworfen während ich da bin!
          "sdf" ist auf "Faulty", array ist degraded
04.12.2019 sdb - stromlos geschaltet
           "Z1N3WJ16" neu eingebaut, als "sdb" erkannt, als spare hinzugefügt->sofortiger resync, Erfolg!
           sdf - Datenkabel abgezogen
           "Z1M626HH" neu eingebaut, als "sdf" erkannt, ABER: Fehler bei gdisk, lehne Platte ab
           "?" aus dieser Serie (2. Platte) wird nicht mehr eingesetzt, ausgebucht!
           Beschaffung von 4 weiteren Platten
11.12.2019 A2,B3 ausgebaut, neues Netzteil
           A2 +"Z1N3WJ16" /sdf (Rolle "2")
           B3 +"Z9CAEV9N" /sdb (Rolle "Spare")

Platten Beschaffung

https://www.alternate.de/html/listings/1458214498740?lk=8323&sort=PRICE&order=ASC&hideFilter=false&showFilter=false&filter_1021=1000.0&filter_2147482612=1037#listingResult