RAID6-2018: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Root (Diskussion | Beiträge) |
Root (Diskussion | Beiträge) |
||
Zeile 44: | Zeile 44: | ||
[A.1 |A.2 |A.3 |A.4 ] [B.1 |B.2 |B.3 |B.4 ] | [A.1 |A.2 |A.3 |A.4 ] [B.1 |B.2 |B.3 |B.4 ] | ||
[HF0CFD|XLHK2N|<s>F7EL9R</s>|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X] | |||
[HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X] | [HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X] | ||
Version vom 30. November 2018, 18:59 Uhr
Info
/dev/md127: Version : 1.2 Creation Time : Sun Nov 8 00:30:12 2015 Raid Level : raid6 Array Size : 23441313792 (22355.38 GiB 24003.91 GB) Used Dev Size : 3906885632 (3725.90 GiB 4000.65 GB) Raid Devices : 8 Total Devices : 8 Persistence : Superblock is persistent Intent Bitmap : Internal Update Time : Tue Oct 16 16:34:23 2018 State : clean Active Devices : 8 Wrking Devices : 8 Failed Devices : 0 Spare Devices : 0 Layout : left-symmetric Chunk Size : 512K Name : Tokio:0 UUID : 39c0b55f:74c0ab19:5f939236:16921f79 Events : 269988 Cage Number Major Minor RaidDevice State A3 0 8 81 0 active sync /dev/sdf1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WMC130F7EL9R A4 1 8 65 1 active sync /dev/sde1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC134LLA4YE A1 2 8 49 2 active sync /dev/sdd1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC134HF0CFD A2 3 8 33 3 active sync /dev/sdc1 ata-WDC_WD4000FYYZ-01UL1B2_WD-WCC133XLHK2N B1 6 8 113 4 active sync /dev/sdh1 ata-HGST_HDN724040ALE640_PK2338P4HGJ6RC B2 5 8 97 5 active sync /dev/sdg1 ata-HGST_HDN724040ALE640_PK2338P4HGDRYC B4 4 8 17 6 active sync /dev/sdb1 ata-HGST_HDN724040ALE640_PK1334PCKNY90X B3 7 8 1 7 active sync /dev/sda1 ata-HGST_HDN724040ALE640_PK1334PEHYT9XS
Lage der Platten
[A.1 |A.2 |A.3 |A.4 ] [B.1 |B.2 |B.3 |B.4 ] [HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X] [HF0CFD|XLHK2N|F7EL9R|LLA4YE] [HGJ6RC|HGDRYC|HYT9XS|KNY90X]
Beschaffung
Es sollen schrittweise alle Platten durch 8 TB Exemplare ersetzt werden.
https://www.alternate.de/html/listings/1458214498740?order=ASC&lk=8323&showFilter=false&hideFilter=false&disableFilter=false&filter_-1=3500&filter_-1=142900&filter_1021=8000.0&filter_2147482612=1037
Ereignisse
May 09 01:22:50 tokio kernel: blk_update_request: I/O error, dev sdf, sector 7010129740 May 09 01:22:53 tokio kernel: blk_update_request: I/O error, dev sdf, sector 7010129740 Jul 26 01:22:52 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521277045 Jul 26 01:22:54 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521277045 Jul 26 01:22:57 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521278897 Jul 26 01:22:59 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6521278897 Oct 18 01:18:41 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6620009643 Oct 18 01:18:44 tokio kernel: blk_update_request: I/O error, dev sdf, sector 6620009643 27.11.2018 9 Uhr Ausfall von 2 Platten, sieht aus wie ein kurzes "Power Fail" Event 11 Uhr Anfrage wegen zu wenig Platz, Reduziere Sicherungen von 10 auf 7 Lösche die Sicherungsverzeichnisse 7+8+9 stelle den Ausfall von 2 Platten fest rebuild von Platte sdd 28.11.2018 rebuild von Platte sdg I/O Fehler bei Platte sdf aus der Vergangenheit entdeckt Beschaffung einer neuen 8TB Platte, soll "sdf" ersetzen 30.11.2018 neue Platte als 9. Platte hinzugehängt --add-spare & --replace angestossen + ata-ST8000VN0022-2EL112_ZA1CY63J (sdi) - ata-WDC_WD4000FYYZ-01UL1B2_WD-WMC130F7EL9R (sdf)